• 15″ high resolution display with LED backlight 9-waveform on screen touch screen optional
• User customized NIBP measuring cycles up to 5-phase
• Versatile clinical calculations for application convenience
• 9 traces on-screen waveforms and maximal up to 13
• Data export and software upgrade
• HL7 protocol, Bed to bed view and 12-lead ECG available
• 360-degree visible indicator with 3-level alarm
• Li-ion battery up to 2.5 hours continuous monitoring
• Integral 3-channel thermal recorder
Comprehensive calculations for clinical application
• Hemodynamics calculation
• Respiration calculation
• Oxygenation calculation
• Drug concentration calculation
• Renal function calculation
Specifications
ECG
• Input dynamic range: ±(0.5mVp~5mVp)
• Differential input impedance: ≥10MΩ
• Bandwidth: 0.05~150Hz (Diagnostic)
• 0.5~40Hz (Monitoring)
• 1~20Hz (Operation)
• CMRR: ≥90dB (Diagnostic)
• ≥105dB (Monitoring & Operation)
• Sensitivity selection: ×1/4, ×1/2, ×1, ×2, ×4 and Auto
• Sweeping speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
• HR measuring range: 15~350bpm
• HR accuracy: ±1% or ±2bpm, whichever is greate
• Pacemaker pulse detection and rejection function
RESP
• Measuring range: 0~120rpm
• Measuring accuracy: ±5% or ±2 rpm, whichever is greater
TEMP
• Measuring range: 21.0~50.0°C
• Measuring accuracy: ±0.2°Cfrom 25~45°C
NIBP
• Technique: Oscillometric method
• Typical measurement time: <30 seconds (adult cuff)
• NIBP measuring range SYS: 40~275mmHg (Adult), 40~200mmHg (Pediatric), 40~135mmHg (Neonate)
• NIBP measuring range DIA: 10~210mmHg (Adult), 10~150mmHg (Pediatric), 10~95mmHg (Neonate)
• NIBP measuring range MAP: 20~230mmHg (Adult), 20~165mmHg (Pediatric), 20~110mmHg (Neonate)
• NIBP measuring accuracy (mean difference): ±5mmHg
• NIBP measuring accuracy (standard deviation): 8mmHg
• NIBP measurement mode: Manual, Auto, STAT, Multi-cycle mode
• Auto measuring intervals: 1-480min
SpO2
• Technique: Dual-wavelength optical method
• Measuring range: 0%~100%
• Measuring accuracy: Arms is not greater than 2% for
• SpO2 range 70~100%.
• PR measuring range: 30~250bpm
• PR measuring accuracy: ±2bpm or ±2%, whichever is greater
• Low perfusion performance: As low as 0.3%
CO2
• Technique: Infrared optical method
• Sampling mode: Sidestream or Mainstream
• Measuring range: 0~150mmHg
• Measuring accuracy: 0~40mmHg ±2mmHg, 41~70mmHg ±5% of reading, 71~100mmHg ±8% of reading, 101~150mmHg ±10% of reading
• Flow rate: 50ml/min ±10 ml/min (Sidestream)
Cerebral State Monitoring (CSM)
• EEG sensitivity: ±400µV
• Noise level: <2µVp-p, <0.4µV rms (1~250Hz)
• CMRR: >140dB
• Input impedance: >50Mohm
• CSI and update: 0-100. filter: 6-42Hz, 1 sec. update
• EMG%: 0-100 (logarithmic) filter: 75-85 Hz, 1 sec. update.
• BS%: 0-100. filter: 2-42 Hz, 1 sec. update
IBP
• Technique: Strain gauge transducer
• Input sensitivity: 5μV/V/mmHg
• Measuring range: -50~300mmHg
• Measuring accuracy: ±2% or ±4mmHg, whichever is greater
• Measuring positions: ART, RAP, PA, LAP, CVP, ICP, AUXP1, AUXP2
• Calibration: zero calibrating
Cardiac Output (C.O.)
• Blood temperature measuring: range: 23-43°C, accuracy: ±0.5°C
• Injecta temperature measuring: range: 0-20°C, accuracy: ±0.5°C
• Measuring range: 0.2~20 L/min
• Measuring accuracy: ±0.2 L/min or ±10%, whichever is greater
Other
• Power supply: AC 100V-240V, 50/60Hz, 60VA
• Built-in lithium battery: 11.1V/4400mAh
• Display: 12.1 inch TFT display
• Alarming method: 3 levels audible-visible alarm
• Networking: Ethernet
Standard configuration
ECG, Respiration, SpO2, PR, NIBP, Temperature
Options
Touch Screen, 2-IBP, EtCO2, Nellcor SpO2, SunTech NIBP, 12-lead ECG,Cardiac Output, Cerebral State Monitoring, Central Monitor Station,Multi-Gas Monitoring